MW (Z) electromagnetic drum brake model:
MWZ-100; MWZ-160; MWZ-200; MWZ-250; MWZ-315; MWZ-400; MWZ-500; MWZ-630; MWZ-710; MWZ-800
Operating Conditions
· Environmental temperature: -25 ℃~+40 ℃
· AC 380V, 50Hz power supply. MWZ products are DC power supply with a rated voltage of 220V
There should be no flammable, explosive, or gas or conductive dust that can corrode metals or damage insulation in the working environment around the brake
· Relative humidity: The relative humidity of the air should not exceed 90%. The altitude of the place of use should not exceed 2000m.
· Outdoor rain and snow erosion or corrosive gases and media should use anti-corrosion (based on actual reports) products.
When there are special requirements, they should be negotiated and determined during the ordering process
Meets the standard
· The installation dimensions, braking torque parameters, and technical requirements of this series of brakes comply with the JB/T7685-2006 standard.
Application
MW (Z) electromagnetic drum brakes are widely used for deceleration and parking braking of mechanical drive devices such as lifting, transportation, metallurgy, mining, ports, docks, and construction machinery.